Subsites Follow
R-50 Residential Zone.
A. Permitted principal uses of buildings and structures are as follows:
(1) Detached single-family dwellings units.
(2) Essential services.
B. Permitted accessory uses of buildings and structures are as follows:
(1) Fences and walls subject to the provisions of Subsection 15-12.17.
(2) Off-street parking.
(3) Private residential swimming pools.
(4) Satellite dish antennas, subject to the provisions of Subsection 15-5.2.
(5) Sheds (garden, storage, or tool).
C. Conditional uses, subject to the provisions of Section 15-5. of this chapter, are as follows:
(1) Same as permitted in the R-75 Residential Zone District.
D. Signs:
(1) Same as permitted in the R-75 Residential Zone District.
E. Area, yard and building requirements:
(1) Minimum lot area: 5,000 square feet.
(2) Minimum lot width: 50 feet.
(3) Minimum lot depth: 100 feet.
(4) Minimum front yard setback: 20 feet.
(5) Minimum side yard setback: 5 feet.
(6) Minimum combined side yard setback: 15 feet.
(7) Minimum rear yard setback: 20 feet.
(8) Minimum accessory building side and rear yard setback: 5 feet.
(9) Maximum building height: 35 feet and 2 ½ stories.
(10) Maximum percent building coverage: 30 percent.
F. Exemption to the minimum lot area, lot depth and rear yard setback requirements:
(1) Notwithstanding the minimum lot area, lot depth and rear yard setback requirements set forth in Subsection E. above, the following lot area, lot depth and rear yard setback requirements shall apply only to lagoon, or other waterfront, detached single-family building lots shown on a final major subdivision plat and/or minor subdivision plat filed on or before November 1, 1987:
(a) Minimum lot area: 4,500 square feet minimum.
(b) Lot depth: 90 feet.
(c) Rear yard setback: 20 feet; 15 feet if a bulkheaded lot.
(2) The minimum lot area of a specified lot is less than 5,000 square feet or bulkhead has been required landward of the lot line. Requirements are as follows:
(a) No part of a dwelling shall be closer than 20 feet from the bulkhead if the location of the bulkhead is equal to or greater than 90 feet as measured from the front property line.
(b) No part of a dwelling shall be closer than 15 feet from the bulkhead if the location of the bulkhead is less than 90 feet as measured from the front property line.
(c) All parts of a dwelling shall be in line with the rear setback of existing dwellings on either side of the subject property.
(d) No accessory structure shall be constructed closer than 15 feet to the bulkhead.